logo

CPCCBC4001A: Apply building codes and standards to the construction process for low rise buildings

   

Added on  2022-09-14

29 Pages4625 Words17 Views
CPCCBC4001A Apply building codes and standards to the construction process for low rise
building: Assessment 3
What you have to do
Make any assumptions you need to, but be sure to include them as part of your assessment.
Question 1 – Project 1
This question relates to Project 1. You will need the Project 1 documentation and access to
the relevant volume of the Building Code of Australia.
You are required to undertake a BCA compliance check for the dwelling in Project 1.
Present it in a format which is easy to follow and understand.
When you are checking compliance against a document such as a Standard or the Building
Code of Australia, it is useful to present your information in a table. This makes it easy for
you, or anyone who picks up your document, to follow your assessment. An example of the
headings you may want to use is shown below.
Assessment 3, LA017847 CPCCBC4001A, Edition 4 1
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April 2014

Class of building project:
Ground Floor:
Class 1a (Single dwelling, detached house)
Class 10a- Double garage 32.78m2
First Floor:
Class 1a (Single dwelling, detached house)
Front boundary fence:
Class 10b
Applicable Australian Standards:
AS 3786- Smoke alarms
AS 4586- Slip resistance
AS 1680 lighting in bathrooms & laundries
BCA
Section
and
Part
BCA Performance
Req.
Proposed Project Complies
Y/N
Fire
Safety
P2.3.1;
cl
3.7.1.3
Protection from the
spread of fire- fire
separation. External
walls must be at least
External wall is 1500mm from boundary,
less gutter overhang of 450mm = 1050mm
from boundary
Yes
2 Assessment 3, LA017847 CPCCBC4001A, Edition 4
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April, 2014

900mm from
boundary or fire-
resisting
Fire
Detectio
n and
early
warning-
smoke
alarms
P2.3.2;
cl
3.7.2.3
Smoke alarm on each
storey
Yes, upstairs gallery & downstairs at base
of stairs
Yes
P2.3.2;
cl
3.7.2.3
In hallway servicing
bedrooms
Yes Yes
P2.3.2;
cl
3.7.2.3
On the ceiling Yes Yes
P2.3.2;
cl
3.7.2.2
(a)
Interconnected Not Specified No
P2.3.2; Connected to mains Yes Yes
Assessment 3, LA017847 CPCCBC4001A, Edition 4 3
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April 2014

cl
3.7.2.2
(a)
power
Health
and
Amenity
P2.4; cl
3.8.2.2
Room heights
Habitable
room 2.4m
Kitchen /
bathroom /
laundry /
pantry / garage
2.1m
All downstairs room heights are
2.450m
Garage height is 2.525m
All upstairs room heights are
2.450m
Yes
P2.4.3;
cl
3.8.3.2
Facilities
Kitchen sink
and food
preparation
facilities
Bath or shower
Washtub and
washing
machine space
Food prep facilities provided
1bath, 3 showers
Washtub and washing machine
space provided
Toilet and washbasin provided
Yes
4 Assessment 3, LA017847 CPCCBC4001A, Edition 4
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April, 2014

Toilet and
washbasin
cl.
3.8.3.3
Toilet door
opening
outwards/slidi
ng /removable/
1.2m clear
space
Powder room door opens inwards,
and does not have 1200mm clear
space (1000mm to shower). Must
change door.
Unsuited & bathroom have
1200mm clear space.
No
P2.4.4;
cl
3.8.4.2
Light to habitable
rooms:
Windows which
are minimum
10% of floor
area.
Or
Roof lights of at
least 3% of
floor area
Room Area of
room
Window size
as % of area
Complies
?
Study 9.9m2 2.29m2=23.13
%
Yes
Dining 12.8m2 2.29m2=17.89
%
Yes
Living 15.13m
2
4.77m2=31.53
%
Yes
Family 20.52m
2
4.77m2=23.25
%
Yes
Meals 12.25m
2
4.56m2=37.22
%
Yes
Bed 1 21.40m
2
6.69m2=31.26
%
Yes
Assessment 3, LA017847 CPCCBC4001A, Edition 4 5
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April 2014

Bed 2 12.35m
2
2.17m2=17.57
%
Yes
Bed 3 11.43m
2
1.88m2=16.45
%
Yes
Bed 4 10.99m
2
2.17m2=19.75
%
Yes
Rumpu
s
29.04m
2
7.87m2=27.1% Yes
Kitche
n
19.09m
2
3.08m2=16.13
%
Yes
P2.4.4; cl
3.8.4.3
Light to non-
habitable
rooms:
instead of
natural light,
bathrooms
Laundry 6.48 m2 0.49m2 =7.56% Yes,
with
light
Unsuited 8.16m2 1.01m2 =
12.38%
Yes,
Bath 9.52m2 1.62m2 = Yes
6 Assessment 3, LA017847 CPCCBC4001A, Edition 4
© New South Wales Technical and Further Education Commission, [2014] (TAFE NSW – WSI), Archive version 1, April, 2014