This assignment is based on the CANADIAN HOME BUILDERS’ ASSOCIATION OF BC BC Building Code Part 2, focusing on plan checking illustrations. The document includes ten drawings, representing plans submitted for building permits, and identifies areas of non-compliance with the BC Building Code. The assignment analyzes a site plan, elevations (front, right, rear, and left), a foundation plan, main floor plan, second floor plan, and roof truss layouts, assessing their adherence to specific sections of the BC Building Code. Key issues addressed include missing dimensions in the site plan, excessive unprotected openings in the front elevation, beam size, joist accessibility, door requirements, and lintel specifications. The solutions provided highlight areas where the plans do not conform to the code, referencing specific sentences within the BC Building Code. The assignment provides an overview of building plans, helping students understand building codes and their application. Desklib provides past papers and solved assignments for students.
tabler-icon-diamond-filled.svg

Contribute Materials

Your contribution can guide someone’s learning journey. Share your documents today.
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
BC Building Code Part 2
Assignment 1: Plan Checking Illustrations
Instructions
The ten drawings in this document, are samples of plans that could be submitted,
along with all required information, at time of applying for a Building Permit. There
may be missing information or information on the drawings that do not conform to
the BC Building Code. Use these to answer the questions in Assignment 1: Plan
Checking.
1
tabler-icon-diamond-filled.svg

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Site Plan
2
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
The site plan does not conform to the requirements of the BC building codes as some dimensions
are missing.
Front Elevation
The total area of unprotected openings in the front elevation is higher than recommended.
According to Sentences 9.10.15.4.(1) and (2) of the BC building codes, a maximum of 9% of the
total exposed face is permitted.
3
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Right Elevation
Right elevation conforms to the BC building codes for elevations
4
tabler-icon-diamond-filled.svg

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Rear Elevation
Rear elevation conforms to the BC building codes for elevations
Left Elevation
5
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Left elevation conforms to the BC building codes for elevations
6
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Foundation Plan
Beam number 8 does not conform to Sentence 9.23.4.2.(3) of the BC building codes. The beam
should be increased in size to 4.0m.
7
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
The joists 9 and 10 are accessible by a staircase and must conform to Sentence 9.23.4.2.(1) of the
BC building codes.
Main Floor Plan
8
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Door number 11 should have automatic closure or be fitted with weather strips to prevent gases
and fumes from entering the dwelling units according to Sentence 9.36.2.7.(1) of the BC building
codes.
Joist 12 is not accessible by a staircase and should conform to Sentence 9.23.4.2.(1) of the BC
building codes
The lintel 15 does not conform to Sentence 9.23.12.3.(1) of the BC building codes.
9
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Second Floor Plan
10
tabler-icon-diamond-filled.svg

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
This plan conforms with set BC building Codes for walls and water proofing as per Sentence
9.29.2.1.(1) and 9.8.3.2.(1) for stairs and steps
Cross-Section A
This plan conforms with set BC building Codes for steps, stairs, fans and ventilations as per
Sentence 9.8.2.2.(1) and 9.32.3.4.(1)
11
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Cross-Section B
This plan conforms with set BC building Codes for roofing and ventilations as per Sentence
9.23.4.2.(1)
The walls conform to Sentence 9.10.9.16.(2) and (3)
12
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
Main Floor Level Roof Truss Layout
13
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
This plan conforms with set BC building Codes for roofing and ventilations as per Sentence
9.23.4.2.(1)
Second Floor Level Roof Truss Layout
14
Document Page
CANADIAN HOME BUILDERS’ ASSOCIATION OF BC
This plan conforms with BC building codes for roof truss setting as per Sentence
9.23.3.4.(1)