Technical Features of Reinforced Concrete Frame Construction

Verified

Added on  2023/04/08

|24
|3859
|77
AI Summary
This report offers a precise discussion on the technical features of reinforced concrete frame construction, including footing system, floor system, structural system, services, roofing systems, and general quality. The information provided is based on an examination of an already constructed medium rise, reinforced concrete building.

Contribute Materials

Your contribution can guide someone’s learning journey. Share your documents today.
Document Page
CPCC5018 ASSESSMENT 9
[Author Name(s), First M. Last, Omit Titles and Degrees]
[Institutional Affiliation(s)]

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
INTRODUCTION
Reinforced concrete frame construction is one of the numerous methods that is used in
the building and design of structures. Concrete frame structures tend to be quite common or
otherwise the most come of current construction globally. Just as the name goes, this building
type is composed of a frame or a skeleton that is made of concrete. The horizontal members of
the frame are known as beams while the vertical members are called columns. Human beings
circulate on the flat beams of concrete known as slabs. The column tends to be the most
significant member of concrete framed buildings as it is the main element that carries the load of
the building (Carson, 2016). Damage to the beam or slab of a concrete frame structure will have
an effect on just one floor while damage to the column is able to bring the entire building down.
The main objective of reinforced concrete frame construction is to transfer the load from
the upper parts of the building also known as the super structure to the lower parts including the
foundation referred to as the substructure. This insinuates that the size of the structural elements
of the structure may be increased or reduced depending on the amount of load that needs to be
transferred. This renders reinforce concrete frames a very ideal construction technique for use in
structurally sound buildings. Reinforced concrete is thus commonly used for single storey as well
as multiple storey construction in both residential and commercial buildings where transfer of
large amount of load are needed.
The purpose of this report is to offer a precise discussion on the technical features of
reinforced concrete frame construction. Six wide areas are to be examined and extensively
analyzed including the footing system, floor system, structural system, services, roofing systems
as well as general quality. The information provided in this report is pegged on an extensive
Document Page
examination of an already constructed and completed medium rise, reinforced concrete building.
Photographs, borrowed from various sources, are use in the illustration of the various aspects of
the discussion alongside simple sketches which offer more refined clarification (Dolan &
Hamilton, 2019). Only the areas stated in the assignment have been examined for the purposes of
simplicity. The paper inevitably comes along with a few mistakes owing to the limited
experience and knowledge of the author.
FOOTING SYSTEM
Part 1: Description the type of footing system
Footings are the constructions that aid in the transfer of loads from the structure and
superstructure of a building to the foundation. The design of a footing mainly aims at enhancing
and ascertaining the transmission of loads to the subsoil in a safe manner which is as well
economical and free from any movement that is perceived to be unacceptable during the process
of construction and by far throughout the projected life of the structure or the building in general.
A number of factors are taken into consideration in the design and choice of a foundation
design. Among such factors include the type of soil, the proposed period of construction the
structural loadings, challenges or problems associated with construction as well as economic
factors among other considerations (Ghaffarzadeh, Jafari & Talebian, 2014). Of all these
considerations and factors, the structural loading alongside the conditions of the soil tend to be
the most considered when it comes to footing design. A footing system that is precisely, properly
and accurately designed would ensure elimination or otherwise on the maximum lower
differential settlements that would take place when the soil is subjected to stressing due to the
imposed load of the structure or building.
Document Page
Two footing systems or designed were adopted in this structure: a 150 mm thick
structural raft slab that had an edge that has been stiffened alongside integral beams that pass
over the piers that have been driven into a shale foundation (Ghaffarzadeh, Jafari & Talebian,
2014). The raft footing serves to spread the load inclusive of the dead and live load from the
structure and superstructures over a large surface area of the base in order to reduce the load per
unit area. The piers on the other hand were used as a bypass for the reactive soil and aided in the
transmission of the superstructure load that was at the edge of the beam to a level that was lower
of the subsoil in which there ease the existence of a suitable ABP.
A pier foundation is composed of numerous cylindrical columns that have large
diameters and are used in the support of the superstructure as well as in the transfer of the super
imposed loads to the stable and firm strata below. Pier foundation stands some feet above the
ground level and is also known as post foundation. Masonry or concrete pier and drilled caissons
are the main type of pier foundation footing commonly used. In the above pictures, the former
foundation footing system has been adopted. Masonry or concrete piers are usable depending on
the stratum level and in most cases used go as high as 5m in which masonry piers are used. The
depth of the bed and the nature of the soil determine the shape and size of the pier.
Part 2: Section through a typical footing system
The arrangement of the structural members on the foundation footing system is as shown below

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
Typical section through mate-line column and pier
Part 3: Section of foundation footing drainage
STRUCTURAL SYSTEMS
Part 1: How such a frame supports the load of the building
The structural connections create a balance in the building structure against such forces
as compressive and tensional forces. The structure is basically a connected frame of members
where each of the members is connected firmly to each other. Such connections are known as
Document Page
moment connection meaning that there os a grip connection between two members which are
connected to each other. The structural connections as well aid in the facilitation of the transfer
of the load from the super structure to the stable stratum below. The sketch below illustrate the
common structural components of reinforced concrete frame building
Structural system of the building
Part 2: Details of the types of connections between the structural members
Column to footing connections facilitate the transfer of the load from the ground floor
level through the columns into the foundation where the load is distributed over the foundation.
Beam to column footing facilitates the transfer of large super imposed loads from the upper
floors through the columns to the stable stratum.
Document Page
Column to beam connection
Beams are used in transmitting and transferring horizontal loads (Guo, Xu, Song, Wang
& Zhang, 2017). Colum-beam connections aid in the transmission of the dead and live loads
from the occupants of the structure as well as the interior furnishes adequately to the columns
which then ensure the transmission of the very load to the foundation footing depending on the
position of the foundation footings.
Beam to slab connection

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
The slab forms the platform on which most of the circulation and movement of human
beings and objects occur hence the center of acting of both the dead and live loads that come
from within the structure. Beam-to-slab connection ensures there is effective transmission of the
load from the floor of the structure to the beams which further transfer the load to the columns
and finally to the foundation footing in which the load is finally distributed underground.
Footing to column connection
Footing to column connection is used in the transfer of the load including both dead and
live loads from the column to the basement or underground surface of the building. This ensures
that all the load that come from the super structure is effective transferred through the column-
footing joint hence resulting in stability (Mishra, Dwivedi, Mishra & Dwivedi, 2016).
Document Page
FLOOR SYSTEMS
Part 1: Description of the floor system that has been used
The choice of the floor system is normally a thorough aspect and consideration in almost
all the aspects of any building or structure inclusive of its design, construction as well as its
anticipated future usefulness. At times a need arise to compromise the construction of s structure
since the final choice in most cases has to meet numerous contradictory criteria.
The floor system used in the upper levels of the building is reinforced concrete floors.
Concrete floor systems exist in various forms and are used in the provision of thermal comfort as
well as other advantages. The floor systems can be either on-ground, suspended or a combination
of both. Conventional concrete is found to be containing high amount of embodied energy. From
the provided pictures of middle rise building, the upper levels have on-ground concrete floor
system. Slab-on-ground concrete floors have two variants: waffle pod slabs and conventional
slabs having deep excavated beams (Mishra et al., 2016).
Part 2: Construction sequence to produce this component of the structural element
Construction sequence of on-ground concrete slab
i. Planning how to place the concrete
ii. Preparation of the ground
iii. Fixation of edge of formwork
iv. Installing service pipes
v. Laying concrete underlay
vi. Fixing steel reinforcement in the beams
Document Page
vii. Fixing steel reinforcement in the slabs
viii. Placing and compacting the concrete
ix. Finishing the slab surface
x. Curing the concrete slab
Part 3: Layers of reinforcement that will be in the floors
There will be two layers of reinforcement in the floors: reinforcement in the beams and
reinforcement in the slabs. The beams are used in the transfer of the dead load of concrete slab to
the columns while the slabs will be used in transferring and supporting both live and dead loads.
The live loads will be those of the occupants of the building while dead load will be of such
equipment as furniture and the load of the concrete slab itself. The minimum recommended slab
reinforcement cover thickness is often in the range of between 20 and 30 mm which is a factor of
the conditions of the environment that is prevailing throughout the service life of the building.
The 20 mm thickness will be applicable to environments that are mostly dry climate while the 30
mm applies to the seaside location. The needed covered is maintained only through the use of
unique stands known as spacers. The spacers must not be affected by such processes as corrosion
and need to be placed about every one meter (Montuori & Muscati, 2016).
Part 4: Information provided on the tag
The bar tags are used for identification of the various steel bars. They provide information on
the properties of the steel. Among the available information on the tags, include the number of
pieces of the bars in the shipment of the rebar, the various bent bar dimensions, the total weight
and bar markings.

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
WALL SYSTEMS
Part 1: Photographs of the wall system(s) utilised in the design of the structure
Concrete frame and brick walls under construction
Water insulation detail Wall flashing details
Document Page
Part 2: Do the walls add to the structural stability of the building?
Depending on the intention of the design of the brick walls of the structure, they may be
structural or just be used as partition wall. However, by the fact that the walls are made of bricks
and cement mortar and have reinforce concrete as the frame, the walls tend to have loading
bearing abilities to a small extent. The external walls used in the structure are load bearing owing
to the noticeable physical properties of being thicker or full-brick-thick (Montuori & Muscati,
2016). Such a property aids in the transmission of loads from the above beams to the beneath
slab. The walls are reinforced vertically and horizontally using steel bars that are having very
small diameters of about 6 mm. The internal walls are not load bearing and instead mostly act as
partitioning walls that separate the various functional spaces frim each other. The partition walls
offer a separation of the slab area into different compartments depending on the functional usage
and are hence not expected to transmit any major loads.
SERVICE SYSTEMS
Part 1: Storm Water Control
Water harvested from the surfaces is treated to be clean and thud dischargeable into any
approved water course without necessarily being taken through the water treatment process. The
construction of the building taken into consideration the effluents from two main areas: the
ground area and the roof.
The design of the roof has been done in such a way that it easily and effectively enables a
fall. The choice of the covering of the roof determines the fall of the same roof and the fall of a
roof also determine the choice of the material covering for the roof. Storm water is controlled
using open drainage channels and gutters (Ning, Yu & Li, 2016). The gutters are placed at the
Document Page
roof deck where they collect rainwater that falls on the roof of the building, which is then further
channelled by downpipes into the various drainage channels that are positioned with
consideration given to the slope of the site. The intensity of the rainfall, the collection area and
the number of downpipes that are used as well as their efficacy determine the size of the gutter
and the downpipe that have been used in the building.
The hardscapes areas have been paved and have concrete box channel lay. The area to be
drained and the shape of the pave area play a significant role in the determination of the size of
the channel and gully that are to be used. From the channels, the effluents are directed into a silt
pit before they are able to join the main street.
Stormwater drainage channel

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
Part 2: The services supplied to the building
Communication and Electricity
The main distribution center for electricity and the telecommunication mast are placed by
the main entrance into the building. The distribution cables are mainly underneath and pass by
the footing slab into the building. Inside the building is a surface mounted wiring system that
utilizes bracket fix directly to the concrete panel (Ning, Yu & Li, 2016). The service cables are
run below the slab for the first level of the building.
Part 3: The requirements for ‘fire stops’ to all penetrations, with reference to the BCA
Clause C3.15 outlines the installation of a service which penetrate the element of a
building except for the external roof or wall which is needed to have an FRL to be installed such
that the integrity of fire related element that is being penetrated is maintained.
Document Page
C3.15 (a) and (b) permit the installation to be usable should it be composed of the same
materials as well as installed using the very methods as prototype assembly that has been tested
in accordance with AS4072.1 as well as AS1530.4
Fire stop collars which are installed on PVC pipes or plastics are a commonly used
meaning of maintaining FRL of roofs and walls. Nonetheless, installers, designers alongside
builder certifiers should ensure the installed has undergone testing in accordance with AS4072.1
and AS1530.4 for the specific circumstance.
C3.15 (c) and (g) permit an avalanche of services that can be installed provide they are
installed as per AS/NZS 1668.1 or the Specification C3.15 as needed.
AS4072.1 outlines the requirement for the evaluation, interpretation of the results of tests,
installation as well as certification of the sealing systems about penetrations via separating
elements of buildings that are needed to bear an FRL or a resistance to incipient fire spread if
applicable (Zhang, Hou & Ou, 2016)
Clause 3.2 of AS4072.1 outlines in cases a certain penetration sealing system is intended
to be used in vertical and horizontal elements of construction, each of the orientations has to
undergo testing.
Methods of Prevention of the spread of fire through penetration
Penetration Firestop Systems
There exist two types of penetration fire stopping that are commonly used in the modern
buildings:
Document Page
Penetration Firestop systems which involve the systems which are able to protect the
penetration which goes all the way via the barrier be it a wall or floor. Generally, sealing is done
on both sides of the penetration using proper system.
Membrane Penetration Firestop systems define the systems which protect penetrations
which go through just part of the barrier as opposed to the whole barrier. Among the examples of
the Membrane Penetration Firestop systems include sink drains, outlet boxes or even conduits
which lead to the space above the ceiling of the building from the black box. Membrane
Penetration Firestop systems adopt the same products as well as similar trends in the protection
of the openings even through there are exceptions which enable them to become unprotected
should the opening be small (Taranath, 2016). This means there are limits in the size as well as
density of the protected membrane penetrations provided within a rating separation.

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
Passive fire protection systems are those that offer a restraint on the spread of fir and
smoke offering barriers to their physical features and position to prevent the smoke and fire from
spreading. Passive fire protection aids in the prevention or otherwise slowing down of the spread
of fire from the room where the fire begins to the other spaces in a building hence reducing or
minimizing the damage as well as offering more time to the occupants of the building for
emergency occupation to seek an area of refuge.
Passive fire protection systems
Document Page
Active Fire Protection
This is an important part of fire protection which is normally characterized by the
systems and items that need a specific amount of response and motion so as to work as opposed
to passive fire protection. In other words, active fire protection systems are those systems which
have a direct role to play in case of the occurrence of fire. Such systems as gas flooding, fire
alarms, fire sprinkler and fire detection are classified as active fire protection systems owing to
their ability to wither notify and warn the occupants of the existence of fire or automatically put
out the fire (Taranath, 2016).
Fire detection and alarm system
A fire alarm is classified as an active fire protection which either manually or
automatically sense fire or its impacts and does one or more of the following tasks: showing the
zone or location of the activated detector, alerts the building occupants, summons the fire service
automatically, begins controls functions that are ancillary fire related in the affected building.
Fire protection fittings
Document Page
Part 4: Australian Standards are relevant to these methods
The Australian Standards relevant to the methods of prevention of the spread of fire through
penetration is AS 4072.1
ROOF SYSTEM
Part 1: The structural roof system chosen building
The roof system of the roof frame has been elaborated in the section on the structural
system of this task (Taranath, 2016). The sketch shown below is indicative of where the roofing
elements will be placed in the building for the purposes of clarification.
Roof structural system
Part 2: The type of roof cladding used
The roof of the building will be cladded using concealed-fixed LYSAGHT KLIP-LOK
406. This is a very strong, durable and versatile roof cladding that can also be used as wall
cladding. Some of the admirable properties of the cladding material include being a combination
of the strength of steel, lock-action rib design and smart fluted pans in addition to concealed
fastening allowing it to be used on various applications ranging from very low pitches, as low as
1 degrees roofs to those that are horizontally ribbed walling. Fixed LYSAGHT KLIP-LOK 406

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
comes in very long lengths and hence it is possible that a single sheet can run from the ridge to
the gutter without necessarily developing an end laps. Below in a pictorial illustration of the roof
a typical building that has fixed LYSAGHT KLIP-LOK 406 as the cladding, noting no lapping
and open fasteners.
Part 3: The gutter detail for the building
Document Page
Gutter Detail & details of necessary flashing
QUALITY
Part 1: Class(es) and type of surface finish are present on the building
The building has class 3-concrete finish in which in as much as visual appeal is important, less of
it is attached to architectural importance. The interior of the building is finish on 3-coats of vinyl
paint while the exterior has natural stone cladding.
Part 2: Why it is necessary to use clean formwork that is in good condition
Formwork is one of the very fundamental assets of building using concrete. The frames as well
as facing materials have to be continually and frequently cleaned and cleaned for any possible
Document Page
defects to ensure any unwanted cavities, pores or blowholes are not forming. This is the point at
which the technology of extra high water pressure jet is introduced: flow, pressure as well as the
water tools may be adjusted as per the amount of residue that needs to be eliminated from them
formwork hence saving on effort and time (Zhang, Hou & Ou, 2016). This results in ideal
cleaning with no damages to the formwork. The quality of formwork is of paramount
significance when using systems of formwork for facing concrete surface. The surfaces of
concrete that satisfy the demanding requirements of aesthetics may only be generated with the
use of clean formwork. The use of clean formwork ensures elimination of impurities such as dust
and chemicals, which would interfere with the final properties of the concrete achieved. The use
of unclean formwork may result into dry concrete not attaining the required compressive strength
(Zhang, Hou & Ou, 2016)
Part 3: Australian Standard that is relevant to concrete finishes
The relevant Australian Standards to concrete finishes are:
AS 3610
AS 36005; and
nATSPec6
Concrete finishes are categorized into Finishes 1, 2, 3 and 4 which are dependent on the type
of finish and texture of the formwork.

Secure Best Marks with AI Grader

Need help grading? Try our AI Grader for instant feedback on your assignments.
Document Page
References
Carson, B. (2016). Analysis of wall formwork in the Australian multi-storey construction
industry
Dolan, C. W., & Hamilton, H. T. (2019). Prestressed Concrete Applications. In Prestressed
Concrete (pp. 31-61). Springer, Cham
Ghaffarzadeh, H., Jafari, A., & Talebian, N. (2014). Equivalent viscous damping in direct
displacementbased design of steel braced reinforced concrete frames. The Structural
Design of Tall and Special Buildings, 23(8), 604-618
Document Page
Guo, T., Xu, Z., Song, L., Wang, L., & Zhang, Z. (2017). Seismic resilience upgrade of RC
frame building using self-centering concrete walls with distributed friction
devices. Journal of Structural Engineering, 143(12), 04017160
Mishra, R., Dwivedi, A. K., Mishra, R., & Dwivedi, A. K. (2016). Symmetrically and Non
Symmetrically Pattern of Shear Walls. International Journal, 2, 453-455
Montuori, R., & Muscati, R. (2016). A general design procedure for failure mechanism control
of reinforced concrete frames. Engineering Structures, 118, 137-155
Ning, C. L., Yu, B., & Li, B. (2016). Beam-column joint model for nonlinear analysis of non-
seismically detailed reinforced concrete frame. Journal of Earthquake
Engineering, 20(3), 476-502
Taranath, B. S. (2016). Structural analysis and design of tall buildings: Steel and composite
construction. CRC press
Zhang, P., Hou, S., & Ou, J. (2016). A beam–column joint element for analysis of reinforced
concrete frame structures. Engineering Structures, 118, 125-136
1 out of 24
circle_padding
hide_on_mobile
zoom_out_icon
[object Object]

Your All-in-One AI-Powered Toolkit for Academic Success.

Available 24*7 on WhatsApp / Email

[object Object]