This text provides information on various topics related to Electrical Engineering such as 3 phase induction motor, step down transformer, 3 wattmeter method, effects of single phase condition of three phase motors, and phasor diagrams for different conditions. It also discusses the starting and running characteristics of 3 phase caged induction motor.
Contribute Materials
Your contribution can guide someone’s learning journey. Share your
documents today.
Running head: ELECTRICAL ENGINEERING ELECTRICAL ENGINEERING Name of the Student Name of the University Author Note
Secure Best Marks with AI Grader
Need help grading? Try our AI Grader for instant feedback on your assignments.
1ELECTRICAL ENGINEERING Task 1: 1.The value of X as found from the appendix is 858 KV. Now, this is the phase voltage of a balanced three phase 50 Hz star connected generator. Now, the phase voltages are have the magnitude of 858 KV but the phase angles are 0,240 and 120 degrees for phase A,B and C respectively for a star connected system. Phasor diagram: Now, the line voltages VAB, VAC and VBC can be calculated by the vector resultant method. The angle between phase A and C is 120 degree, A and B is 240 degree and B and C is 120 degree. Hence, the resultant vectors of line voltages VAC, VAB and VBC will have angles 120/2 = 60, -120/2 = -60 and -120/2 = -60 degrees respectively. Magnitude of Line voltage VAC =√VAN2+VCN2+2∗VAN∗VCN∗cos60 =√8582+8582+2∗858∗858∗cos60= 1486.1 KV. Similarly, the magnitude of the line voltage VAB VAB =√VAN2+VBN2+2∗VAN∗VBN∗cos(−60)= 1486.1 KV. Also, in the same method the magnitude of line voltage VBC is VBC = 1486.1 KV.
2ELECTRICAL ENGINEERING Hence, in general for a balanced three phase star connection Line voltage =√3∗¿(phase voltage) Final phasor diagram: The time interval between the positive peaks of two successive phases like phase A and phase B is calculated by the following method. The phase angle difference between two phases is 120 degrees. Frequency of both phase waves = 500 Hz. Hence, 500 cycles are completed in 1 sec. Or, 1 cycle completed in 1/500 secs. 360 degrees completed in 1/500 secs. 120 degrees completed in 120/(500*360) = 0.000667 secs = 0.667 msecs. Hence, the time intervals between two positive peaks of two successive phases having a frequency of 500 Hz is 0.667 msecs. The peak value of line voltage = RMS value *√2= 1486.1*√2= 2101.66 KV.
5ELECTRICAL ENGINEERING Task 2: SpeedTorquePhase voltage Phase current Efficiency (%) line current Mecha nical Power N (rpm)T (Nm)V (v)I (A) (3*Vph*Ip h)/P(P=w atts) I (A)P(W) 01.142242.22.20 1491.022242.292.89172.215.91531 3141.022242.0440.873422.0433.53964 5181.12241.9622.073661.9659.66932 7221.082201.814.548791.881.65628 8394.282185.189.0089295.18376.0403 9964.352204.396.3860344.39453.7088 11534.242223.614.696323.61511.9456 12393.882252.823.7811272.82503.4214 12863.412242.433.5559172.43459.2234 13252.982222.043.2858192.04413.486 13572.432221.653.1823171.65345.3144 13881.842241.413.5428481.41267.4459 14121.182251.254.8358011.25174.4799 14350.592251.188.9836591.1888.66098
6ELECTRICAL ENGINEERING As, the 3 phase induction motor is star connected hence the line current is equal to phase current. Plot of torque vs speed: Efficiency vs RPM: 02004006008001000120014001600 0 10 20 30 40 50 60 70 80 90 100 (3*Vph*Iph)/P(P=watts) Speed(rpm) % Effciency Line current vs RPM:
Secure Best Marks with AI Grader
Need help grading? Try our AI Grader for instant feedback on your assignments.
7ELECTRICAL ENGINEERING 02004006008001000120014001600 0 1 2 3 4 5 6 I (A) N (in RPM) line current I (Amp) The 3 wattmeter method is employed for power measurement in the 3 phase and 4 wire circuit. The method can also be employed in 3 phase 3 wire circuit where individual measurement of power is required. Circuit diagram of 3 wattmeter method for star connected load:
8ELECTRICAL ENGINEERING From the above diagram it can be seen that the pressure coil of the three wattmeters are connected to the neutral point which is the common terminal of three impedances. Hence, the total power consumed is P = W1 + W2 + W3 Where, W1 = V1*I1, W2 = V2*I2 and W3 = V3*I3 Task 3: When one of the 3 phase windings of a 3 phase motor fails then the motor will continue or stop running based on the loading condition. If the motor is lightly loaded then the motor will continue to run for some amount of time at reduced speed but if the motor is heavily loaded then the motor will stop running. This condition known as single phase condition of three phase motors. Now, these are effects when one of the three phases fails or disconnected. i)The speed of the motor is reduced. ii)Due to the supply gets misbalanced the motor runs with uneven torque and hence a humming noise is produced. iii)As one of the phase is disconnected but the supply voltage remains the same the current in the remaining two phases will increase and thus damages windings in the remaining phases as they are not usually supposed to meet the increased current. This will ultimately damage the insulation between phases and motor will finally stop. Now, the failure of one of the phase of the motor can be due to several reasons. i)Mechanical disturbance while motor is running may loosen the windings and one of the windings may be disconnected. ii)If the voltage supply to the motor abruptly changes then the current will also change abruptly(if inductances in the windings is low) then the power loss in
9ELECTRICAL ENGINEERING the windings will increase and this damages the coils which will eventually disconnect one or more windings from the system iii)Short circuits may occur between the phases through induction if motor MVA rating is high and gapping between phases is low. This results in high current increase and this may burn out the motor. Task 4: The step down transformer is a transformer in which the primary side voltage is stepped down to the secondary side. A transformer can be single phase or three phase. In case of single phase the input and output voltage has two wires however in case of three phase 3 input and 3 output lines with or without neutral line is there. A transformer can’t be made as a phase changing device thus either 3 phase or single phase transformer is produced. A three phase transformer can be made using either by the combination of three single phase transformers or by using a balanced three phase transformer bank or with a pre-assembled balanced three phase supply that consists of the pairs of single phase windings merged by one laminated core. Hence, the primary and the secondary windings of the three phase transformer can either be delta or star connected. Hence, the four combinations of primary and secondary windings are delta-delta, delta-star, star-delta and star-star. In star connections multiple voltages can be used while in delta connection the voltage level can be increased significantly. Also, there exist another type of connection which is known as ‘interconnected star’ or ‘zig-zag’ connection. In case of star connected 3 phase transformer voltage can be reduced and hence, the required number of turns is reduced and coil lengths are increased which makes it easier for insulating than the delta connected transformers. However, in delta connected transformers each of the delta connected transformer can work independently such as if one gets faulty then the other delta connected
Paraphrase This Document
Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
10ELECTRICAL ENGINEERING transformers can convert 3 phase power at a lower level than the actual. In case of the delta connection the line voltages and phase voltages are equal but the line current is √3times of phase current. The disadvantage of the delta connected 3 phase transformers is that in this connection each of the transformer needs to be wounded for the full line voltage and 1/√3times of line current. This increases the number of turns in the windings and hence larger and more expensive coils are needed. Also, another disadvantage of the delta connected transformers is that there is no neutral connection. However, in star connection three transformers are needed and if one of the transformer gets faulty then the whole group may be shut down. The advantage of star connection is that in this case a neutral wire is there which helps to get rid of extra currents in the circuit when voltage spikes occur and also the star connection is more economical for reduced coil size in transformer. In case of 3 phase step down transformer the voltage in the primary side is stepped up in the secondary side. This is achieved by increasing the number of coil turns in the secondary size than the primary side. The step up transformers are very useful for long distribution of power as in many sites or industries higher voltage requirement is necessary. But, the current from primary to secondary side is reduced to maintain the conservation of power. Task 5: The starting and running characteristics of 3 phase caged induction motor are i)The starting torque of the 3 phase induction motor is very low and hence it can’t start with heavy loads. ii)The torque increases with the speed and hence it is best fitted for pumps, fans and compressors as those require higher torques at high speed.
11ELECTRICAL ENGINEERING iii)The torque of 3 phase induction motor is proportional to square of voltage and hence when voltage is halved the torque becomes one quarter. iv)With the increase of the resistance in the circuit the torque of the motor also increases. v)At the time of starting the induction motor draws more current due to the deficit of back emf voltage. vi)At the time of running when load is maintained at constant level motor reaches steady state. This steady state characteristics can be obtained by using the blocked rotor and no load test. Now, the different stages of the power-torque curve of 3 phase induction motor are shown in the following figure.