Urban Stormwater Design: OSD and Easement Drainage Report
Verified
Added on 2023/06/13
|7
|637
|299
AI Summary
This report covers the OSD and Easement Drainage design for Urban Stormwater Design. It includes OSD System Design using UPRCT method, Orifice Size, Pit and Loss Coefficients, and references to AS 3500.3.
Contribute Materials
Your contribution can guide someone’s learning journey. Share your
documents today.
URBAN STORMWATER DESIGN2 OSD and Easement Drainage 1.Easement Drainage Design; From, AS 3500.3, 2003, Easement width for: Stormwater pipe <= 825= 3.0 m. Stormwater pipe <= 825 mm diameter and Sewer pipe 225 mm diameter= 4.0 m. Available Drainage Diameter,= 525 mm, Adapt Easement Width= 3.0 m Easement overland flow path; From lot 10 – 9 – 8 -7 – 6 – 5 – 4 – 3 – 2 – Point B. 2.OSD System Design using UPRCT method. i.Adjutments for area not draining to OSD Total Site Area=0.5996ha Initial Storage Requirement470 x 0.1=47m3 Storage per area ha47/0.5996=78.39m3/ha Basic PSD= 80 l/s/ha=0.008m3/s PSD adjustment (Vol/PSD adjustment – from AS 3500.3, 2003 Design Charts with 78.39/ha)= 80l/s/ha
URBAN STORMWATER DESIGN3 Final PSD80 x 0.5996= 47.968l/s ii.Orifice Size Peak Discahrge to DCP Q = CIA/360 (Q- discharge in m3/s, C- runoff coefficient, I – 100 year rainfall intensity mm/hr, A – Area) = 0.8 x 224 x 0.5996/360 =0.2984m3/s = 298.47 l/s Weir peak flow Qweir= Inflow to DCP – PSD = 298.47 – 47.97 =250.5/1000 = 0.2505 QWeir= CL H3/2 C – Coefficient of weir H – flow depth over weir in m
URBAN STORMWATER DESIGN4 L – weir length 0.2505= 1.6 x 1 x H2/3 H= 0.07256m Orifice diameter (d) Q= CA√2gh C – Orifice discharge coefficient (0.62) A – area of orifice in m2 g – acc due to gravity 9.81 d – orifice diameter h – water depth above centre of orifice d= 2.505 x 0.00635 /√0.5910.5 = 0.0206 =20.6mm HED Adjustment HED= PSD x√hmin/hmax =47.968 x√¿¿)
Paraphrase This Document
Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
URBAN STORMWATER DESIGN5 =44.12l/s Check with HED exceeds 75% of PSD i.e 35.976,OK Mean discharge= (44.12 + 47.968) / 2 = 46.044 l/s Mean discharge/hectare=46.044/0.5996=76.79l/s/ha SSR From Design Charts for PSD 76.9= 490 m3/ha Needed storage Volume Final SSR= 490 x 0.5996 =293.804 m3 Minimize Nuisance by distributing Storage Using charts for 1 year ARI, percentage of total storage; 0.16 x 293.804= 47.00 m3 Check 450 rcp pipe size from the OSD to the 600 mm rcp in the street. Adequate. Pit and Loss Coefficients Given full outflow from junction pit, upstream pie flow = Qu, flow out of pit = Qo, flow from lateral pipes, flow from tank level = Qg and pit loss coefficient = k,
URBAN STORMWATER DESIGN6 Pit and Loss Coefficients range from 0.5 – 2.5 SWMM sample input data $RAIN A1'1-hour rainfall data for Oolitic, IN' A2'Continous data from 1948 to 1999' *KODEAKODEPR KOVER B0011 *IFORMISTAIDECID IYBEGIYENDIYEARISUM MIT NPTSIFILEANOSTAT B139999119490723199912260124 000.41 *THISTO METRIC KUNITFIRMATCONVF1F2F3 F4F5F6F7 B26001'(2I4,2I2,25I3)' 0.01123 4567 * $ENDPROGRA M
URBAN STORMWATER DESIGN7 References STANDARDS AUSTRALIA. (2015). Australian Standard ™ Plumbing and drainage Part 3: Stormwater drainage.AS 3500.3. VICTORIAN BUILDING AUTHORITHY. (2015). Australian/New Zealand Standard Plumbing and drainage - Part 3: Stormwater Drainage.AS 3500.3.