This report focuses on brownfield regeneration and construction technology, specifically addressing a project involving the demolition and reconstruction of buildings in the United Kingdom. The report details various demolition techniques, including explosive and non-explosive methods, with a focus on safety regulations and the preservation of existing building elements. It further explores the design and selection of structural elements, foundation types, internal finishes, and service installations like HVAC and plumbing. The report also covers roof designs suitable for the location's climate, fire protection measures, and the principles of durability. Architectural and structural drawings are developed to support the construction process. The report's scope includes commercial, industrial and high-rise buildings and meets the requirements of the HK 5CN001 module, emphasizing legislative, technical, and environmental issues within the construction project.
Document Page
Abstract
This is a report that gives details of a proposed demolition methodology and
reconstruction of various buildings in a site which is located in the United Kingdom. In this
project, the existing buildings on the ground shall be demolished before beginning the
reconstruction work. It is worth noting that the parts which shall be determined usable such as
the façade shall be retained and reused in the construction process. However, this shall only
apply after assessing the quality of the façade. In this report, various techniques applied for
demolition process shall be explored. The two types of demolition include use of explosives
and non-explosives. These methods are further divided into wrecking ball, implosion, high
reach arm and stripping out techniques. However, checking on the location of the building,
non-explosive type of demolition shall be applied to spare the surrounding structures and the
people living in the area. In this report, various safety requirement during demolition process
shall be discussed in details since the process is risky and can lead to loss of life and property.
The safety regulations shall base on the requirements of CDM. Considering the façade
retention, the building located on the Princess street shall be spared since it is still in a good
quality. The design and choice of appropriate structural elements shall begin by choosing the
right foundation followed by structural frames. The internal finishes such as the ceilings shall
be discussed. This will be followed by locating services such as HVAC, plumbing and
electrical fittings. Roof types shall also be discussed. However, in this area curved roof will
be the most appropriate since the area experiences heavy snow falls. Additionally, fire
protection and escape root will be discussed in details and finally, the principles of durability
on these elements shall be considered. Architectural and structural drawings shall be
developed which will be used in coming up with new development.