This report details the design of a two-way reinforced concrete (RC) slab for the top floor of a hotel in Kiama, NSW, following the assignment brief provided. The design process includes manual calculations for determining design loads, bending moments, and shear forces. The effective depth of the slab is verified, and reinforcement calculations are performed. The report references relevant academic papers and includes an attached Excel file for supplementary calculations. The design adheres to standard procedures and considers factors such as exposure classification and the selection of torsion reinforcing bars. The project successfully develops a two-way RC slab design suitable for the specified application.
Document Page
Two way RC Slab Design
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
Table of Contents
Introduction......................................................................................................................................2
Manual Calculations........................................................................................................................2
Design loads and Bending moments and shear force diagram....................................................2
Verification of effective depth of slab.........................................................................................5
Calculations for reinforcement.....................................................................................................6
Excel calculations............................................................................................................................8
Conclusion.....................................................................................................................................12
References......................................................................................................................................13
1
Document Page
Introduction
This report brings the overview of the design development of the two way RC slab supported on
its four edges. Here the RC design is developed for hotel top floor. Here the design process
involves both calculations as well as the selection of materials. In the initial stage of the project,
the loads and pressure will be calculated. Then the effective depth of the slab will be calculated.
And also torsion reinforcing bars will be selected.
Manual Calculations
Design loads and Bending moments and shear force diagram
Calculations for Loading
2
Document Page
Exposure classification
3
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
4
Document Page
5
Document Page
Verification of effective depth of slab
6
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
Calculations for reinforcement
7
Document Page
8
Document Page
Excel calculations
9
tabler-icon-diamond-filled.svg

Paraphrase This Document

Need a fresh take? Get an instant paraphrase of this document with our AI Paraphraser
Document Page
10
Document Page
11