Power Transformer Differential Protection Using Current and Voltage Ratios : Report

16 Pages4808 Words336 Views
   

Added on  2020-07-22

Power Transformer Differential Protection Using Current and Voltage Ratios : Report

   Added on 2020-07-22

ShareRelated Documents
Power TransformerDifferential Protection UsingCurrent and Voltage ratios.
Power Transformer Differential Protection Using Current and Voltage Ratios : Report_1
EXECUTIVE SUMMARYIn Electrical Engineering, power system is the greatest topic. There are various devices,machines, tools and instruments used are mentioned. Further, about their protection and effectiveworking. The current report is about the challenges that are faced by transformer in itsprotection. For this, accelerated and efficient differential-relay algorithm which at the time offault separates the transformer from the online grid that prevents it from getting damage orblackout. There should not be any mal-operation performed at the time of algorithm. Moreover,while distinguishing among the operating situation that is between the magnetizing inrushcurrent and fault conditions. Present report highlights the protection of Power transformers ingrid through improved differential protection scheme. It is ratio based scheme and is related toabsolute difference and sum of the current ratio in all phases. Along with this, it is supplementedwith the help of ratio of the absolute variation and summation of both the terminal voltagewinding that is V1 and V2 across attached phase. The algorithm will generate the gaps that willassist in preventing the mal-operation that generally occurs at the time of faulty conditions in 3-phase X-mer differential protection scheme due to transient and magnetic-inrush flow of current.Additionally, there is coinciding inrush current along with internal-fault, and faults with CTsaturation. Finding or information gathering of this project is by using both V/I ratios mentionsthat there will be higher accuracy, more reliability, security as-well-as it will be dependablerelay. The research comprise of various conditions that occur in the power transformers such asinrush-conditions, internal-fault and its simultaneous-inrush. If used for the power transformer, itwill be more accurate, dependable, faster and secure relay. There are various application of activated carbon adsorption where large amounts ofactivated-carbons are used for purification of domestic-and-industrial waste-water. However,there are certain changes in organic abortion as carbon only attracts to non-organic. The organiccompounds are polar or non-polar and depends only on electrostatic interactions. So theseactivated carbon adsorption can be helpful in removing the domestic-and-industrial waste water(Organic and inorganic)These waste can be removed by using the activated-carbons adsorption by using methodssuch as Adsorption isotherms, Column adsorption, Effluent concentration. These are effectivemethods to remove waste from water.
Power Transformer Differential Protection Using Current and Voltage Ratios : Report_2
INTRODUCTIONIndustrialization and increasing needs of humans have changed the way people usetechnological devices. However, in order to run any device or machine there is need of electricalpower that too consistent and reliable. For the reliable supply there is need of effective andSMART grid system with all the devices and machine working at the time of failure. In electricalgrid system there are two main machines that are too expensive and are necessary to beprotected. These are generator/alternator and Transformer (Ali and et. al., 2016). As alternator ison the generating side so if there is any power failure the system is de-attached from main linebut in case of transformer this can not be performed. Due to this purpose there are various typesof protection devices are connected so that it can be protected. For electrical system, transformerare used for transforming voltage from one part to another using mutual induction process. Thereare two main use of it, either it is used as step-up at the time of transferring from grid tosubstation, in industrial or heavy use areas. The other is step-down which is used at distributionnetwork and at homes for smaller application. At grid side there is use of power transformer asthey have higher rating of voltage and current. The machine needs to be protected from twofaults that are internal and external. For the reliable operation, there is need of operation and maintenance so that protectionfrom the faults can be made. Additionally, the devices are used at higher voltage, temperaturewhich makes it expose to high inrush currents and external faults. In order to protect there arevarious protective devices used such as relays, oils and monitor system which are placed basedon rating of transformer. There are various parameters that are overlooked if the faults occur.These are urgency of load, size of system on the basis of the total load. Power transformershaving higher rating, the protection used is percentage differential. It is completely related to thecurrent flowing in the primary and secondary components of machine. All the machines aremade to work at the rated limit however, if the current and voltage value has increased then thereis need of protection. Protective relays are to protect the machine from magnetic-inrush-current,external-faults with CT saturation (Current transformer), simultaneous-inrush with internal-faults(Murugan and et. al., 2017). In transformer, major faults occur due to Inrush current due towhich there can be arcing, noise or wires may even burn. Along with this, at starting oftransformer there is high inrush current. Here, differential protection scheme detecting faults isevaluated. It provides protection based on 3-general methods: overtime current, percentage
Power Transformer Differential Protection Using Current and Voltage Ratios : Report_3
differential relays that is flow of current in protection zone and percentage differential relayswith restraint by harmonics method (Mostafaei and Haghjoo, 2016, Sendilkumar, Mathur andHenry, 2010).The undergoing is to seeks about the identifying the different protection scheme that areused to protect power transformer. The report will especially aim at undertaking protectionsystem using the Differential Protection Using Current and Voltage ratios that will be beneficialfor grid system and is highly reliable at the time of power failure. The study will can be usedacross the globe at any power transformer. A literature review is written which will furtherelaborate the topic. After the literature section, the study focus on various tools and techniquesused to complete the methodology, experimental setup for determining the other areas and after that outcome and relevance arementioned. Without the use of project plan, research can never be completed, so for the completeproject planning Gantt Chart was made. LITERATURE REVIEWIn power protection, grid protection is very important duty to maintained by the electricalengineers. It is required so that continuity and reliability can be maintained even at the time ofblackout, peak loads and surges. Devices such as alternator and transformer that have higherrating are high current and voltage ratios needs greater protection. At the time of issues alternatorcan be separated from main grid system, however, this cannot be performed with transformer sothere is great need of its protection (Bejmert, Rebizant and Schiel, 2014, Rahmati and Sanaye-Pasand, 2015). Ali and et. al. (2016) have noted that using the differential protection transformerwhere they mentioned about the three ways through which internal-fault can be evaluated. Theymentioned that at the time of loaded energization, current and voltage ratio will be greater than 0and will be less than 1 and is completely depended on ratio of I1 and I2. However, through thisonly internal faults can be can be reversed there will be no impact on the external faults. Itscondition will mostly depend on the Differential protection algorithm, it also helps in gettingrobust, secure and dependable relay for power transformers. Murugan and et. al. (2017) whoundertook Empirical Fourier Transform-Based Power Transformer Differential ProtectionHowever, there are various methods mentioned but Sendilkumar, Mathur and Henry (2010) havecarried out their study using the using HS-transform and support vector machine. In this study,they have highlighted the ways like energy and standard deviation which were evaluated using
Power Transformer Differential Protection Using Current and Voltage Ratios : Report_4

End of preview

Want to access all the pages? Upload your documents or become a member.

Related Documents
Report on Protection Method for Power Transformers
|13
|3799
|328

Power Electronics : Assignment
|3
|729
|162

Transformer Testing By Your Name Date
|28
|6844
|412

EEE8082: Post-Exam Assignment on Electrical Power
|14
|1707
|282